·Universal shell: 22.5mm universal shell, with strong versatility in appearance and size.

·Three-proof paint coating on the circuit board: protect the circuit board from moisture, insulation, water and dust, and prevent parts from loosening to meet G3 anti-corrosion standards.

·Convenient wiring: the power supply is represented by red and black, the input terminal is represented by S plus number, and the input terminal is represented by number.

·All-localization: All-localization devices are adopted, with high cost performance and worry-free quality.

·Support a variety of equipment input: emergency stop button, safety door, PNP safety light curtain, expansion module.

technical parameter

rated insulation voltage

picture

SM-C-101.png

1716350795759996.png

model

SM-C-101

SM-C-104

Power supply characteristics

supply voltage

24V DC / A

24V DC

Voltage tolerance

0.85 ~ 1.1

/

voltage range

/

20~30V DC

Current loss

≤90mA (24V DC); ≤240mA (24V AC

≤70mA (24V DC)

Input feature

incoming current

≤50mA (24V DC)

≤70mA (24V DC)

conductor resistance

≤15

≤15Ω

input device

Emergency stop button, safety door, PNP safety light curtain

Safety switch, contact switch

Output characteristics

Number of contacts

3NO + 1NC

4NO + 2NC

Contact material

AgSnO2 + 0.2μm Au

AgSnO2 + 0.2 μm Au

Safe output

/

13, 14, 23, 24, 33, 34, 43, 44

Auxiliary output

/

11, 12 (status indication); Y1, Y2 (fault feedback)

Contact type

/

Forced orientation

Output characteristics

Contact fuse protection

10A gL/gG, NEOZED (normally open contact)

6A gL/gG, NEOZED (normally closed contact)

10A gL/gG, NEOZED (normally open contact)

6A gL/gG, NEOZED (normally closed contact)

Electric shock mechanical life

107 Secondary or higher

107 Secondary or higher

Switching capacity (EN60947-5-1)

AC-15, 5A/230V; DC-13, 5A/24V

AC-15, 5A/230V; DC-13, 5A/24V

Time characteristics

Suction buffer time

≤300ms

≤30ms

Release buffer time

≤30ms

≤20ms

recovery time

≤100ms

≤100ms

Short-term interruption of power supply

20ms

20ms

Environmental characteristics

electromagnetic compatibility

EN 60947, EN 61000-6-2, EN 61000-6-4

frequency of oscillation

10Hz~55Hz

Vibration amplitude

0.35mm

usage temperature

-20℃~+60℃

storage temperature

-40℃~+85℃

relative humidity

10%~90%

altitude

≤2000m

Insulation characteristics

Overvoltage grade

class of pollution

2

250V AC


Rated impulse voltage

6000V (1.2/50us)

6000V (1.2/50us)

Rated impulse voltage

1500V AC, 1min

Electrical clearance and creepage distance

accord with EN 60947-1

認(rèn)證

safety integrity level

SIL3

Performance grade

PLe

Security category

Cat.4


functional block diagram

model

SA101

SA104

functional block diagram


6eeeae108857b6dcb93dde35d1ad0a5.png

b99e36feb1239189c38fcb959588e36.png


Typical application

model

SM-C-101

SM-C-104

Typical application

SA101典型應(yīng)用2.png

SM-C-101典型應(yīng)用1.png

SM-C-101典型應(yīng)用2.png

SM-C-104典型應(yīng)用.png


Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh