欧美日韩免费高清在线观看,旅行者的J桶进雷电将军的J,2021全国精品卡一卡二,欧美成人精品免费观看

Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
Position首頁 > Home > Safety products > Safety Relays 安全控制器 > safety relay
SR-103 safety relay

    As the most important link of safety circuit, safety controller/safety PLC has been more and more recognized by people. However, in the process of using it, there are still many users who are confused. What are the differences between safety relay and ordinary relay? I would like to share with you here. As we all know, we must remember three words about the concept of safety design:

(1) redundancy

(2) Differences

(3) Self-test

    How to construct the safety loop reliability above PLd, the safety controller must become an important link. The safety loop consists of safety input, safety control and safety output, and the safety control "including safety relay, safety controller, safety PLC, etc." realizes the safety control function. Designers match different safety controllers to achieve the reliability level of the safety loop according to the number of products at the input end


SR103 safety relay

1666678722263707.png

Two-channel safety monitoring relay module

· Secure dual-channel module capable of constructing multiple security products

· Performance index E corresponding to ISO 13849-1

· Safety certification of safety category 4

· Built-in self-diagnosis function for fault detection

· You can choose automatic reset or manual reset

· Pass TUV certification


395181ccb7a771e30162f6415dc922a.pngProduct selection1588126326899852.png  image.png

Product selection

Power Supply 

Enter 1CH safely

output

order number

SR103-3A1B

24V AC/DC

Door lock/emergency stop/light 

screen(PNP)

3NO+1NC


explain

Emergency stop button, safety door, PNP safety light curtain, safety carpet


395181ccb7a771e30162f6415dc922a.pngsafety performance

· Performance grade (PL):PLe              

· Security category (Cat.):Cat.4        

· Time (TM): 20 years                    

· Diagnostic coverage rate (DC/DC AVG): 99%       

· Safety level (sil): sil3                 

· Hardware fault margin (hft): 1              

· Safety Failure Score (SFF): 99%       

· Risk failure probability (pfhd): 3.09e-10/h       

· Stop level (Stop Category):0           

Stop level EN     ISO13849

Stop level EN     ISO13849

Stop level EN      ISO13849

Stop level EN      ISO13849

Stop level IEC61508, IEC62061

Stop level IEC61508, IEC62061

Stop level IEC61508, IEC62061

Stop level IEC61508, IEC62061

Stop levelEN 60204-1

   

395181ccb7a771e30162f6415dc922a.pngMain technical parameters

Power supply characteristics

·supply voltage:24VDC

·Voltage tolerance0.85~1.1

·Ac frequency:50Hz~60Hz

·Current loss:≤90mA(24VDC)

Input characteristics

·incoming current:≤50mA(24VDC)

·conductor resistance:≤15Ω

·Input: emergency stop button, safety door, PNP safety light screen

output characteristic

·Number of contacts:3NO+1NC

·Contact material:AgSnO2 +0.2μmAu

·Type of contact: forced guidance

·Contact fuse protection: 10AgL/gG, NEO ZED (normally open contact)

                           6AgL/gG, NEO ZED(the normally closed contact)

·Switching capacity(EN60947-5-1):AC-15,5A/230V;

                                                                         DC-13,5A/24V

·mechanical life:More than 10 times

Time characteristic

·Release buffer time:

         Emergency stop operation:≤30ms

         Power failure:≤100ms

·recovery time:

         Emergency stop operation:≤30ms

         Power failure:≤100ms

·Short-term power interruption:20ms


395181ccb7a771e30162f6415dc922a.png環(huán)境特性參數(shù)

·Environmental characteristic parameters:accord with EN60947,EN61000-6-2,EN61000-6-4

·frequency of oscillation:10Hz~55Hz

·Vibration amplitude:0.35mm

·usage temperature:-20℃~+60℃

·storage temperature:-40℃~+85℃

·relative humidity:10%~90%

·Electrical clearance and creepage distance:accord with EN60947-1

·Overvoltage level:Ⅲ

·class of pollution:2

·the protection grades:IP20

·altitude:≤2000m

·rated insulation voltage:250VAC

·Rated impulse voltage:6000V(1.2/50us)

·dielectric strength:1500VAC, 1min

1655439137185503.png


395181ccb7a771e30162f6415dc922a.pngApplication parameters

functional block diagram

Typical application

1.png

2.png


395181ccb7a771e30162f6415dc922a.png

outline dimension

    Overall dimensions (depth× height× width):

114.5mm×99.0mm×22.5mm

1655439838506616.png


395181ccb7a771e30162f6415dc922a.png

Wiring diagram

Power 

Supply 

image.png

Input 

circuit

safety 

moncee

image.png


single channel

Double-channel short-

circuit detection

Without short circuit detection in two channels

Input

circuit

emergency 

stop 

button

image.pngimage.pngimage.png

exit

image.pngimage.pngimage.png


automatic reset

manual reset

Reset

circuit

image.pngimage.png


automatic reset

manual reset

feedback

loop

image.pngimage.png


Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh