Position首頁 > Home > Safety products > Safe output > Electro-hydraulic safety valve
SCR magnetic induction safety switch


Coded Non Contact Switches


e1101410ac165e6acb3a3afc3f987a9.png

  • Coded non-contact safety switch/magnetic induction switch

  • With high anti-interference ability, the highest safety level certification

  • Meet the requirements of category 3 standards (EN 954-1)

  • IP67, IP69K protection level, high waterproof performance, can withstand high pressure steam cleaning

  • Service life up to 1 million times



 Type selectionimage.png



Product category

Coding type

Magnetic type

RFID type

Pharmaceutical food grade

model

SCP

SCR

SWP

SRM-RMC

SWM-WMC

 Contact configuration

2N/C+1N/O

2N/C+1N/O

2N/C

1NC+1N/O

1N/C

2N/C+1N/O

2N/C+1N/O

Explanation

Multiple selection modes



Product technical description


  • Magnetic induction switch

  • Specified as 80 degrees Celsius, but the design working temperature is up to 100 degrees Celsius

  • Easy to install in narrow frame structure

  • Width 12 mm, can sense height deviation tolerance

  • Heavy-duty 230Vac/24Vdc 2A or medium 1A

  • When used in conjunction with dual-channel safety relays, coded non-contact switches can be used to provide up to

  • Class 4 and Ple to ISO13849-1 protection.

 6794148d1a8.png



Packaging industry

Food industry

machine tool

robot

Pharmaceutical Industry

Other manufacturing industries

48697c.png

 


SCR selection specifications


 Product number

Current and voltage

Contact

Cable

Order number

 SCR-022

(24 VAC/DC)

2N/C

2M


 SCR-025

(24 VAC/DC)

2N/C

5M


 SCR-0210

(24 VAC/DC)

2N/C

10M


 SCR-0221

(24 VAC/DC)

2N/C+1N/0

2M


 SCR-0251

(24 VAC/DC)

2N/O+1N/C

5M


 SCR-0211

(24 VAC/DC)

2N/O+1N/C

10M


 SCR-012

(230 VAC)

1N/C

2M


 SCR-015

(230 VAC)

1N/C

5M


 SCR-0110

(230 VAC)

1N/C

10M


 SCR-012

(230 VAC)

1N/C+1N/O

2M


 SCR-015

(230 VAC)

1N/C+1N/O

5M


 SCR-0110

(230 VAC)

1N/C+1N/O

10M


 Remarks





 standard:

ISO14119 EN60947-5-1EN60204-1 ISO13849-1 EN62061 UL508

Mechanical reliability: B10d

3.3 x 106 running ISO13849-1 under 100mA load, according to system architecture, up to Ple

EN62061 to SIL3 depends on the system architecture

Safety data

8 times per year / 24 hours a day / 365 days Full HD 2.52 x 10-8

 MTTFD

(Life) 47 years MTTFD470 years

Safe channel 1 NC

250Vac 2.0A maximum rating

Safe channel 2 NC

250Vac 2.0A maximum rating

Safe channel 3 NC

Maximum rating 24Vdc 0.2A

 Contact release time

<2ms

 Minimum switching current

10Vdc 1mA

Main material

Certified polyester

 Operating temperature

-25C+80C

Enclosure rating

IP69K(NEMA PW12)IP67(NEMA 6)

Impact resistance

IEC68-2-27 11ms 30g

Vibration resistance

IEC68-2-6 10-55Hz 1mm

Cable type

PVC 6 core 6mm OD conductor 0.25mm2



Safety circuit module


1587443050315847.png

  • Universal safety circuit building module

  • It is a configurable safety control module that supports multiple switch-type safety element inputs

  • Optional 3 groups-6 groups of safety element input

  • Configuration software can be used to set the safety control logic to meet the needs of a variety of field applications.




product name

model

Safe input3CH

Output

Order number

 Safety Relays

SR103 series

1 set of security products

3N/O+1N/C

See product information for details

Safety Relays

SR301 series

3 set of security products

2N/O

Safety Relays

SM601 series

6 groups of safety products

2N/O+4Tr

 Explanation




Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh